N700-750HF
HYUNDAI HiRUN
High Performance AC Drive Inverter
|
|
|
|
Various Applications
& Load
Compatibility |
Conveyor & Transport Machines |
-
Conveyor -
Elevator and Parking Machine -
Crane & Hoist -
Factory Automation |
Metal & General
Machinery |
-
Metal Spreader -
Wire Drawing Machine -
Press & Cutter -
Centrifugal Separator & Agitator |
Fan & Pump |
-
Air Conditioning & Dust Collecting
Fan -
Cooling Tower |
Textile Machine |
-
Spinning Machine -
Tender & Sewing Machine |
Washing Machine |
|
|
Model |
Applicable Motor
Capacity |
Rated Capacity
|
400V
|
480V
|
N700-750HF |
75kW
/ 100HP |
103.2kVA |
123.8kVA |
Improved Control
Performance |
-
Advanced Sensorless Vector Control at
Ultra Low Speed Excellent control performance with all
machines thanks to the improvement of torque characteristics at low speeds.
-
Sensorless vector control: 200% or greater at 0.5Hz
-
Sensored vector control: 150% or greater at 0Hz
-
Excellent Response Speeds and Toque
Control Performance
Improvement of the torque response
characteristic minimizes the speed deviation when the load is changed. (Quick response to a sudden load change
is realized.)
-
Improvement of Reduced Torque
Characteristic -
Expansion of Multi-speed Control Function -
Stable and Strong Torque Operation -
Expansion in The Field Weakening
Operation Range |
Easy Operation and
Maintenance |
Various Inverter Display Functions |
All the data of the inverter are
displayed on the monitor.
-
The trip data of each phase are
displayed in case of input phase loss and output short
-
Temperature on the IGBT
-
Others (In-Out voltage, current,
frequency, DC voltage, input power, RPM of motor, rotation direction,
frequency change, PID Feedback, accumulated operating time
(hour, minute), total power up time (hour, minute), error and trip count
display) |
|
RUN(0,1,2) Relay Control Terminal Added |
Run output terminals (RN0,1,2) are
added for user’s convenience |
|
12 User Group Codes |
Users can save the preferred codes
(Max. 12) for fast and easy operation and set or adjust data in accordance
with the characteristics of the loads. |
|
Convenient Operation |
Operator
-
Large LED and convenient settings
(code/parameter)
-
Noise resistant design (Max. 10m cable)
OPE-N7 (standard) has parameter copy
function. |
|
Maintenance |
Detachable cooling fan and independent
DC bus capacitor make replacement and
maintenance easy and simple |
|
|
Inverter
Model |
N700-750HF |
Applicable Motor (4P) |
75kW
/ 100HP |
Rated Capacity
(kVA) |
400V
|
103.2 |
480V
|
123.8 |
Rated Output Voltage |
3-phase,
380 ~ 480V (±10%) 50/60Hz
|
Rated Input Voltage |
3-phase,
380 ~ 480V (This corresponds to supply voltage.)
|
Rated Output Current (A) |
149 |
Braking |
Dynamic Braking (short-time) |
External dynamic braking unit (option) |
Minimum Value of Resistor (Ω) |
6 |
Weight (kg) |
70 |
Dimensions (W
x D x H) (mm) |
420
x 740 x 320
|
Control Method |
Space vector modulation PWM system |
Output Frequency Range |
0.1
~ 400Hz |
Frequency Accuracy |
Digital : ±0.01% of Max. frequency, Analog : ±0.2% (25±10℃) |
Frequency Resolution |
Digital setting : 0.01Hz, Analog setting : Max. frequency /
4,000 |
Voltage
/ Frequency
Characteristic |
V/F control (constant torque, reduced torque), free V/F
control, sensorless vector control |
Overload Capacity |
150% / 60sec |
Acceleration/Deceleration Time |
0.1
~ 3600. Sec (Linear/curve setting) |
DC Braking |
Performs at start ; under set frequency at deceleration, via
an external input
(braking force, time and temperature frequency)
|
Input |
Frequency
Setting |
Operator |
Set by up/down key |
External Signal |
Input voltage : DC 0~+10V, -10~+10V (Input impedance 10KΩ) /
Input current : 4~20mA (Input impedance 180Ω) |
Forward
/ Reverse / Start / Stop |
Operator |
Run key/ Stop key (Change FW/RV by function command) |
External Signal |
FW Run/Stop (No contact), RV set by terminal assignment (NO/NC
selection), 3-wire input possible |
External Port |
Set by RS485 |
Thermistor
Input Terminal |
1 terminal (PTC characteristics) |
Output |
Intelligent
Output Terminal
|
Analog Voltage, Analog Current, Pulse Line Output |
Display Monitor |
Output Frequency, Output Current, Motor Torque, Scaled Value
of Output Frequency, Trip History, I/O Terminal Condition, Input Power, Output Voltage |
Standard Application |
Low voltage directive 72/73/EEC & EMC directive
2004/108/EC, CE, UL, cUL |
Operator |
OPE-N7 (4-digit LED) |
|
|